Why is my AutoSort not starting up properly?

Why is my AutoSort not starting up properly?

If your AutoSort Connect is triggering a shutdown as soon as it starts up, partially starting up and then showing a blank screen, or other strange behaviour, your incoming power may be the issue. Double check that the RPS voltage selector switch is in the proper position. If the incoming power to the RPS is 115VAC, and the switch is left in the default 230VAC position, this can cause the sorter to not start up properly.
    • Related Articles

    • Why is My AutoSort Connect screen blank on startup?

      If the screen of your AutoSort Connect turns on and then goes blank when starting up, the backup battery in the control may need to charge. Open up the control and look at the back of the display for the board with the small fan. If L1 and L2 LEDs ...
    • Can I run multiple AutoSort-Connects off one RPS?

      No. You must use one RPS to power each AutoSort Connect.
    • Are AutoSort Touch kits compatible with ProSort Touch?

      Yes, AutoSort Touch kits are compatible with ProSort Touch. ProSort Touch kits are not available and have been replaced by the AutoSort Touch kits.
    • Updating AutoSort Connect using a USB drive

      Update AutoSort Connect using the USB drive 1. Download the update files Install_ASC_USB.zip. 2. Log in to the control. 3. Eject the USB drive (Administration > Diagnostics > Eject USB). 4. Press Yes. DO NOT press Okay yet. 5. Remove the USB drive ...
    • Why should I upgrade to the AutoSort-Connect?

      The AutoSort Connect has network connectivity, which allows you to monitor your scale from your phone or tablet. You can view reports and review daily counts from the comfort of your office or home, rather than needing to fight your way through the ...