EPF error

EPF error

On the old PEC-PLUS the EPF error means the EEPROM has failed. To fix this a factory restore is required. Power off the control, and while holding down the up and down arrows, power on the control. If the error appears again, the control likely needs to be replaced.
    • Related Articles

    • Local database error

      If your AutoFlex is displaying a local database error, follow the link below to find a troubleshooting flowchart to help diagnose and solve the issue. https://phason.ca/img/kb/005/database-error.html
    • Check light sensor error

      This error means that the control is not seeing a valid reading from the light sensor. In most circumstances this is a sensor/wiring problem that needs to be addressed. Please see DOL’s Technical User Guide for some more information.
    • Alarm Codes and Error Messages

      ALARM MESSAGE POSSIBLE CAUSE POSSIBLE SOLUTION High Temperature Alarm The temperature has gone above the high temperature alarm point. Try to lower the temperature by turning heaters down or off, or by increasing or turning on cooling elements (such ...