Yes, if it is a fixed-speed fan it can be wired to your minimum ventilation fan and set to switch on the fan if the temperature gets too high. This is useful if your main controller fails.
Users may want to run the FC-1T-1VDC in manual mode rather than running off the temperature probe. The FC-1T-1VDC does have a software manual override menu that can be used to manually set the output. The controller will stay at the overridden output ...
Yes. This would most often occur when upgrading an existing AFX2 to an AFX3. You may take a database backup of the existing AFX2 and then restore that file on the AFX3 to mirror the settings onto the new control.
Step 1 - From the controller with all of the settings you wish to use; Go to Main menu > Administration > Diagnostics > Backup Database Step 2 - From the Diagnostics page, go to Eject USB and push Yes. Step 3 - With this "It is now safe to remove the ...