No. The AutoFlex Connect is not compatible with the DOL104 0-10v sensor. The DOL104 0-20mA sensor is unofficially supported. It acts the same as a DOL114, and if that is selected and it is wired up like a 114 it will work, just with only the humidity ...
To control heat lamps within the AutoFlex Connect-2 you would use a VAC-1 board. https://phason.ca/pdfs/vac-1.pdf Heat lamps can be controlled via a VAC-1 module, assigning the output as “Variable Heating”. Once you have the module configured, the ...
The AutoFlex Connect II comes with an upgraded touchscreen and new enclosure colour. The software is the same for both models. This means there is nothing new to learn when you upgrade to the new AutoFlex Connect II.
You can connect 4 BinTrac loadcells to an AutoFlex Connect. That is: 4 loadcell Summing Boxes can connect to one BinTrac Indicator Box. The Indicator Box connects to a HOUSELINK Serial Interface. One HOUSELINK can connect to an AutoFlex Connect.
For the AutoFlex Connect 2, the ratings are: Control voltage 100 to 240 VAC, 50/60 Hz, 0.9 A WARNING: To be installed with 10 A maximum overcurrent protection or equivalent.