Problem Fans turn off and actuators close when zone temperature rises Possible Cause Tunnel mode is active Possible Solution Set tunnel turn off to "No" for stages you do not want affected by tunnel mode.
Check if there are other temperature sensors assigned to control that equipment group. A temperature sensor in a different room or an outdoor sensor could be incorrectly assigned to control for that group and is being added into the averaging ...
Yes, the PLUS TOUCH has two available zones, so you can use one for controlling the room's main equipment based off the average of multiple probes, and a second one to control equipment off a different probe.
Problem Temperature does not change Possible Cause Possible Solution There are no working temperature probes enabled or connected Make sure at least one working probe is enabled. The control is in temperature test mode. If the TEST LED is on, the ...