If the screen of your AutoFlex Connect turns on and then goes blank or blue when starting up, the backup battery in the control may need to charge. Open up the control and look at the back of the display for the board with the small fan. If L1 and L2 ...
If the screen of your AutoSort Connect turns on and then goes blank when starting up, the backup battery in the control may need to charge. Open up the control and look at the back of the display for the board with the small fan. If L1 and L2 LEDs ...
When a feed-loop is set to run on a duty cycle the proximity alarm should go off if the loop runs for the maximum duration without the proximity sensor being triggered. If these alarms are not occurring, check the proximity alarm setting. This can be ...
If for some reason you want to prevent the alarm relay on the AFX from setting off a separate alarm it is wired to when the relay goes off, you would make the change shown below:
If your Supra-Touch temperature reading is stuck on one single temperature you may have the temperature manually overridden. Go to the Menu, then Manual Override. Either hit Auto All to change all outputs and sensors back to automatic operation, or ...