Can I use misting, fogging, and soaking in a THI controlled equipment group?
Yes! THI misting/fogging/soaking looks exactly the same as in a cooling equipment group, only you will have THI values as the low/high/max setpoints rather than temperature values. There are three videos explaining the three modes available in the ...
Does the DOL58 need an additional power supply?
As per the AutoFlex Connect and DOL58 user manuals, the DOL58 requires connection to the IN-4, as well as a separate 11-30vdc power supply. This could be a standalone 12vdc or 24vdc power supply, or, you can use the 12vdc terminal on the backboard of ...
Why do I measure full voltage output when the control says it should be less?
The control and expansions need to have a load connected for the triac to give a correct output. If there are no mats (load) connected to the triac output, the output will always read full voltage, no matter what you set the control to. As soon as ...
General Principles of Troubleshooting
Note: These are guidelines only. Opening the control and any work on wiring should only be done by a trained professional as there could be live voltage and a risk of shock or death. Swapping control covers from a working unit to a non-working unit ...
How to get rid of OSD display settings menu that appears on my AutoFlex Connect?
The AutoFlex Connect display has its own built-in settings menu (OSD) for contrast, brightness, etc., like any other monitor or display. This is set at the factory, and should not appear on its own. If the menu ever appears, try carefully ...